Maximum height
40 ftHow tall the building may be.
“Building height, max. 40”RS-20 › 2.2.3 · Arlington code · read 2026-10-02
Arlington, TX · zoning record
The dimensional standards that govern what you can build in the RS-20 district, straight from Arlington's ordinance, with every figure quoting its source. Check a specific address to see how these rules apply to a real lot.
Free · Every figure cited · Read from the current code (2026-10-02)
In Arlington's RS-20 district the maximum height is 40 ft (Arlington code RS-20, read 2026-10-02).
In Arlington's RS-20 district the minimum lot size is 20,000 sq ft (Arlington code RS-20, read 2026-10-02).
In Arlington's RS-20 district the minimum lot width is 100 ft (Arlington code RS-20, read 2026-10-02).
In Arlington's RS-20 district the minimum lot depth is 150 ft (Arlington code RS-20, read 2026-10-02).
In Arlington's RS-20 district the minimum interior side setback is 10 ft (Arlington code RS-20, read 2026-10-02).
In Arlington's RS-20 district the minimum street-side setback is 15 ft (Arlington code RS-20, read 2026-10-02).
In Arlington's RS-20 district the minimum rear setback is 10 ft (Arlington code RS-20, read 2026-10-02).
In Arlington's RS-20 district building coverage may not exceed 50% (Arlington code RS-20, read 2026-10-02).
In Arlington's RS-20 district the minimum dwelling size is 2,200 sq ft (Arlington code RS-20, read 2026-10-02).
These are the letter-of-the-law limits for the base RS-20 district. Overlays (historic, neighborhood plan, and similar) can tighten them; a specific address check resolves the overlays that actually apply.
How tall the building may be.
“Building height, max. 40”RS-20 › 2.2.3 · Arlington code · read 2026-10-02
Smallest conforming lot.
“Single family 20,000 s.f.”RS-20 › 2.2.3 · Arlington code · read 2026-10-02
Narrowest conforming lot.
“Figure 2.2.3-A: C. Lot Dimension Measurement Single family 100”RS-20 › 2.2.3 · Arlington code · read 2026-10-02
Shallowest conforming lot.
“4. Lot depth, min. (ft) 150”RS-20 › 2.2.3 · Arlington code · read 2026-10-02
Required space from a side line.
“Figure 2.2.3-B: D. Setback Measurement Side 10”RS-20 › 2.2.3 · Arlington code · read 2026-10-02
Required space from a side street on a corner lot.
“6. Street side, min. (ft) All roadways 15”RS-20 › 2.2.3 · Arlington code · read 2026-10-02
Required space from the rear line.
“Side 10 Rear 10”RS-20 › 2.2.3 · Arlington code · read 2026-10-02
Share of the lot the building footprint may cover.
“Lot coverage, max. (%) Single family 50”RS-20 › 2.2.3 · Arlington code · read 2026-10-02
Smallest floor area a dwelling may have.
“2. Gross living area min. (s.f.) Single family 2,200”RS-20 › 2.2.3 · Arlington code · read 2026-10-02
Every figure above is quoted verbatim from the current ordinance. We never substitute a typical-for-zone default: a field absent from the record shows nothing, not a guess.
See how these standards resolve on a specific parcel, with the overlays that actually apply, in about 20 seconds.
Free to score · No card, no signup · All 50 states