1. Zoning
  2. Augusta, GA
  3. R-1D

Augusta, GA · zoning record

R-1D zoning in Augusta.

The dimensional standards that govern what you can build in the R-1D district, straight from Augusta's ordinance, with every figure quoting its source. Check a specific address to see how these rules apply to a real lot.

Free · Every figure cited · Read from the current code (2026-10-02)

R-1D dimensional standards.

These are the letter-of-the-law limits for the base R-1D district. Overlays (historic, neighborhood plan, and similar) can tighten them; a specific address check resolves the overlays that actually apply.

Maximum height

45 ft

How tall the building may be.

“exceed a height of two and a half (2-1/2) stories or forty-five (45) feet”12-1 Permitted Uses: The following uses may be permitted in an R-1D district upon › 12-4 · Augusta code · read 2026-10-02

Minimum lot size

4,000 sf

Smallest conforming lot.

“a minimum area of four thousand (4,000) square feet”12-1 Permitted Uses: The following uses may be permitted in an R-1D district upon › 12-2 · Augusta code · read 2026-10-02

Minimum lot width

40 ft

Narrowest conforming lot.

“Every lot in an R-1D Zone shall have a minimum width of forty feet”12-1 Permitted Uses: The following uses may be permitted in an R-1D district upon › 12-2 · Augusta code · read 2026-10-02

Interior side setback

5 ft

Required space from a side line.

“All detached dwellings shall have a side setback not less than five feet.”12-1 Permitted Uses: The following uses may be permitted in an R-1D district upon › 12-3 · Augusta code · read 2026-10-02