Maximum height
35 ftHow tall the building may be.
“Maximum height cannot exceed 35 feet (see Section 3.2.6 for additional height provisions).”3.6.3 Residential Manufactured Home Park (R-MP) › 3.6.3 · Memphis code · read 2026-10-02
Memphis, TN · zoning record
The dimensional standards that govern what you can build in the R-MP district, straight from Memphis's ordinance, with every figure quoting its source. Check a specific address to see how these rules apply to a real lot.
Free · Every figure cited · Read from the current code (2026-10-02)
In Memphis's R-MP district the maximum height is 35 ft (Memphis code 3.6.3 Residential Manufactured Home Park (R-MP), read 2026-10-02).
In Memphis's R-MP district the minimum lot size is 4,000 sq ft (Memphis code 3.6.3 Residential Manufactured Home Park (R-MP), read 2026-10-02).
In Memphis's R-MP district the minimum lot width is 40 ft (Memphis code 3.6.3 Residential Manufactured Home Park (R-MP), read 2026-10-02).
In Memphis's R-MP district the minimum front setback is 25 ft (Memphis code 3.6.3 Residential Manufactured Home Park (R-MP), read 2026-10-02).
In Memphis's R-MP district the minimum interior side setback is 5 ft (Memphis code 3.6.3 Residential Manufactured Home Park (R-MP), read 2026-10-02).
In Memphis's R-MP district the minimum rear setback is 15 ft (Memphis code 3.6.3 Residential Manufactured Home Park (R-MP), read 2026-10-02).
In Memphis's R-MP district building coverage may not exceed 40% (Memphis code 3.6.3 Residential Manufactured Home Park (R-MP), read 2026-10-02).
In Memphis's R-MP district at least 20% of the lot must be open space (Memphis code 3.6.3 Residential Manufactured Home Park (R-MP), read 2026-10-02).
These are the letter-of-the-law limits for the base R-MP district. Overlays (historic, neighborhood plan, and similar) can tighten them; a specific address check resolves the overlays that actually apply.
How tall the building may be.
“Maximum height cannot exceed 35 feet (see Section 3.2.6 for additional height provisions).”3.6.3 Residential Manufactured Home Park (R-MP) › 3.6.3 · Memphis code · read 2026-10-02
Smallest conforming lot.
“Lots must have a minimum lot size of 4,000 square feet and have a minimum lot width of 40 feet.”3.6.3 Residential Manufactured Home Park (R-MP) › 3.6.3 · Memphis code · read 2026-10-02
Narrowest conforming lot.
“Lots must have a minimum lot size of 4,000 square feet and have a minimum lot width of 40 feet.”3.6.3 Residential Manufactured Home Park (R-MP) › 3.6.3 · Memphis code · read 2026-10-02
Required space from the front line.
“Each home shall have a front setback of at least 25 feet.”3.6.3 Residential Manufactured Home Park (R-MP) › 3.6.3 · Memphis code · read 2026-10-02
Required space from a side line.
“Each home must be set back at least five feet from the side property line and 15 feet from the rear property”3.6.3 Residential Manufactured Home Park (R-MP) › 3.6.3 · Memphis code · read 2026-10-02
Required space from the rear line.
“Each home must be set back at least five feet from the side property line and 15 feet from the rear property”3.6.3 Residential Manufactured Home Park (R-MP) › 3.6.3 · Memphis code · read 2026-10-02
Share of the lot the building footprint may cover.
“Building coverage may not exceed 40% of the total lot area.”3.6.3 Residential Manufactured Home Park (R-MP) › 3.6.3 · Memphis code · read 2026-10-02
Share of the lot that must stay open space.
“Open space equal to 20% of the total site area must be provided as either public or private common open space.”3.6.3 Residential Manufactured Home Park (R-MP) › 3.6.3 · Memphis code · read 2026-10-02