Maximum height
30 ftHow tall the building may be.
9.1200: GR, General Residential District › 9.1200.3 · Plano code · read 2026-10-02Row as published
“Residential Uses 1 story, 30 feet (up to 50% of attic”
Plano, TX · zoning record
The dimensional standards that govern what you can build in the GR district, straight from Plano's ordinance, with every figure quoting its source. Check a specific address to see how these rules apply to a real lot.
Free · Every figure cited · Read from the current code (2026-10-02)
In Plano's GR district the maximum height is 30 ft (Plano code 9.1200: GR, General Residential District, read 2026-10-02).
In Plano's GR district the maximum height is 1 story (Plano code 9.1200: GR, General Residential District, read 2026-10-02).
In Plano's GR district the minimum lot depth is 90 ft (Plano code 9.1200: GR, General Residential District, read 2026-10-02).
In Plano's GR district the minimum front setback is 10 ft (Plano code 9.1200: GR, General Residential District, read 2026-10-02).
In Plano's GR district the minimum interior side setback is 5 ft (Plano code 9.1200: GR, General Residential District, read 2026-10-02).
In Plano's GR district the minimum street-side setback is 5 ft (Plano code 9.1200: GR, General Residential District, read 2026-10-02).
In Plano's GR district building coverage may not exceed 50% (Plano code 9.1200: GR, General Residential District, read 2026-10-02).
In Plano's GR district the code requires 1 parking space per dwelling unit (Plano code 9.1200: GR, General Residential District, read 2026-10-02).
In Plano's GR district the minimum dwelling size is 800 sq ft (Plano code 9.1200: GR, General Residential District, read 2026-10-02).
These are the letter-of-the-law limits for the base GR district. Overlays (historic, neighborhood plan, and similar) can tighten them; a specific address check resolves the overlays that actually apply.
How tall the building may be.
9.1200: GR, General Residential District › 9.1200.3 · Plano code · read 2026-10-02Row as published
“Residential Uses 1 story, 30 feet (up to 50% of attic”
Story cap where the code sets one.
9.1200: GR, General Residential District › 9.1200.3 · Plano code · read 2026-10-02Row as published
“Residential Uses 1 story, 30 feet (up to 50% of attic”
Shallowest conforming lot.
“Minimum Lot Depth 90 feet 90 feet”9.1200: GR, General Residential District › 9.1200.3 · Plano code · read 2026-10-02
Required space from the front line.
“All other 10 feet 10 feet”9.1200: GR, General Residential District › 9.1200.3 · Plano code · read 2026-10-02
Required space from a side line.
“All other 5 feet 5 feet”9.1200: GR, General Residential District › 9.1200.3 · Plano code · read 2026-10-02
Required space from a side street on a corner lot.
“Corner Lot (street side) 5 feet (See also Sec. 13.500.3 )”9.1200: GR, General Residential District › 9.1200.3 · Plano code · read 2026-10-02
Share of the lot the building footprint may cover.
“Maximum Lot Coverage 50% total 50% total”9.1200: GR, General Residential District › 9.1200.3 · Plano code · read 2026-10-02
Off-street parking spaces the code requires for each dwelling unit.
“Parking Requirements 1 space per dwelling unit”9.1200: GR, General Residential District › 9.1200.3 · Plano code · read 2026-10-02
Smallest floor area a dwelling may have.
“Minimum Floor Area per Dwelling 800 square feet 800 square feet”9.1200: GR, General Residential District › 9.1200.3 · Plano code · read 2026-10-02
Every figure above is quoted verbatim from the current ordinance. We never substitute a typical-for-zone default: a field absent from the record shows nothing, not a guess.
See how these standards resolve on a specific parcel, with the overlays that actually apply, in about 20 seconds.
Free to score · No card, no signup · All 50 states