1. Zoning
  2. Tulsa, OK
  3. OL

Tulsa, OK · zoning record

OL zoning in Tulsa, OK: height, setbacks and lot size

The dimensional standards that govern what you can build in the OL district, straight from Tulsa's ordinance, with every figure quoting its source. Check a specific address to see how these rules apply to a real lot.

Free · Every figure cited · Read from the current code (2026-10-02)

In Tulsa's OL district the maximum height is 35 ft (Tulsa code Table 15-3: O, C and I District Lot and Building Regulations, read 2026-10-02).

In Tulsa's OL district the minimum street frontage is 50 ft (Tulsa code Table 15-3: O, C and I District Lot and Building Regulations, read 2026-10-02).

In Tulsa's OL district the minimum front setback is 10 ft (Tulsa code Table 15-3: O, C and I District Lot and Building Regulations, read 2026-10-02).

In Tulsa's OL district the maximum floor-to-area ratio is 0.4 (Tulsa code Table 15-3: O, C and I District Lot and Building Regulations, read 2026-10-02).

OL dimensional standards.

These are the letter-of-the-law limits for the base OL district. Overlays (historic, neighborhood plan, and similar) can tighten them; a specific address check resolves the overlays that actually apply.

Maximum height

35 ft

How tall the building may be.

“Maximum Building Height (feet) 35”Table 15-3: O, C and I District Lot and Building Regulations › Maximum Building Height (feet) › OL column · Tulsa code · read 2026-10-02

Minimum street frontage

50 ft

Lot length that must touch a street.

Row as published“Minimum Street Frontage (feet) [4] 50 50 50 – 50 50 – – 50 50 50”
Table 15-3: O, C and I District Lot and Building Regulations › Minimum Street Frontage (feet) › OL column; note [4]: Minimum street frontage requirements apply to townhouse developments, not to individual townhouse units. · Tulsa code · read 2026-10-02

Front setback

10 ft

Required space from the front line.

Row as published“Street [1] 10 10 10 10 10 10 – – 10 10 10”
Table 15-3: O, C and I District Lot and Building Regulations › Building Setbacks (feet) › Street › OL column; note [1]: Garage doors must be set back at least 20 feet or 20 feet from the back of the sidewalk, whichever is greater. · Tulsa code · read 2026-10-02

Floor-to-area ratio

0.4

Max floor area ÷ lot area.

Row as published“Maximum Floor Area Ratio (FAR) 0.40 0.50 2.00 8.00 0.50 0.75”
Table 15-3: O, C and I District Lot and Building Regulations › Maximum Floor Area Ratio (FAR) › OL column · Tulsa code · read 2026-10-02

Uses in OL

  • single-familyAllowed by right
  • two-familyAllowed by right
  • townhouseAllowed by right
  • multi-familyAllowed by right
  • manufactured-homeNot allowed
“Detached house P S S S S S S S · Duplex P P P P P P P S · Townhouse P P P P P P P P · Multi-unit House P P P P P P P P – – – Section 40.250 · Apartment/Condo P P P P P P P P – – – Section 40.030 · Manufactured housing unit – – – – – S S …”single-family: Table 15-2.5: O, C, and I District Building Type Regulations for Household Living › Detached house › OL column | two-family: Table 15-2.5: O, C, and I District Building Type Regulations for Household Living › Duplex › OL column | townhouse: Table 15-2.5: O, C, and I District Building Type Regulations for Household Living › Townhouse › OL column | multi-family: Table 15-2.5: O, C, and I District Building Type Regulations for Household Living › Multi-unit House + Apartment/Condo › OL column | manufactured-home: Table 15-2.5: O, C, and I District Building Type Regulations for Household Living › Manufactured housing unit › OL column · Tulsa code · read 2026-10-02