1. Zoning
  2. Richmond, VA
  3. R-8

Richmond, VA · zoning record

R-8 zoning in Richmond.

The dimensional standards that govern what you can build in the R-8 district, straight from Richmond's ordinance, with every figure quoting its source. Check a specific address to see how these rules apply to a real lot.

Free · Every figure cited · Read from the current code (2026-10-02)

R-8 dimensional standards.

These are the letter-of-the-law limits for the base R-8 district. Overlays (historic, neighborhood plan, and similar) can tighten them; a specific address check resolves the overlays that actually apply.

Maximum stories

3 stories

Story cap where the code sets one.

“No building shall exceed three stories in height.”DIVISION 7.2. R-8 URBAN RESIDENTIAL DISTRICT › 30-413.19 · Richmond code · read 2026-10-02

Minimum lot size

3,000 sf

Smallest conforming lot.

“Single-family detached dwellings shall be located on lots of not less than 3,000 square feet in area.”DIVISION 7.2. R-8 URBAN RESIDENTIAL DISTRICT › 30-413.14 · Richmond code · read 2026-10-02

Rear setback

5 ft

Required space from the rear line.

“There shall be a rear yard with a depth of not less than five feet.”DIVISION 7.2. R-8 URBAN RESIDENTIAL DISTRICT › 30-413.15 · Richmond code · read 2026-10-02

Maximum building coverage

65 %

Share of the lot the building footprint may cover.

“Lot coverage in an R-8 district shall not exceed 65 percent of the area of the lot.”DIVISION 7.2. R-8 URBAN RESIDENTIAL DISTRICT › 30-413.16 · Richmond code · read 2026-10-02

Sources

Every figure above is quoted verbatim from the current ordinance. We never substitute a typical-for-zone default: a field absent from the record shows nothing, not a guess.

Other Richmond districts on record.

Check a real Richmond lot against R-8.

See how these standards resolve on a specific parcel, with the overlays that actually apply, in about 20 seconds.

Free to score · No card, no signup · All 50 states