1. Zoning
  2. Garden City, UT
  3. MFR

Garden City, UT · zoning record

MFR zoning in Garden City, UT: height, setbacks and lot size

The dimensional standards that govern what you can build in the MFR district, straight from Garden City's ordinance, with every figure quoting its source. Check a specific address to see how these rules apply to a real lot.

Free · Every figure cited · Read from the current code (2026-10-01)

In Garden City's MFR district the maximum height is 35 ft (Garden City code § 11C-1305, read 2026-10-01).

In Garden City's MFR district the minimum street-side setback is 20 ft (Garden City code § 11C-1307, read 2026-10-01).

In Garden City's MFR district building coverage may not exceed 60% (Garden City code § 11C-915, read 2026-10-01).

In Garden City's MFR district the accessory structure setback is 3 ft (Garden City code § 11C-906, read 2026-10-01).

In Garden City's MFR district an accessory dwelling unit may be up to 1,500 sq ft (Garden City code § 11C-2300, read 2026-10-01).

In Garden City's MFR district the minimum dwelling size is 600 sq ft (Garden City code § 11A-200, read 2026-10-01).

In Garden City's MFR district a fence may be up to 8 ft tall (Garden City code § 11C-908, read 2026-10-01).

MFR dimensional standards.

These are the letter-of-the-law limits for the base MFR district. Overlays (historic, neighborhood plan, and similar) can tighten them; a specific address check resolves the overlays that actually apply.

Maximum height

35 ft

How tall the building may be.

“No building shall be erected to a height greater than 35 feet.”§ 11C-1305 · Garden City code · read 2026-10-01

Street-side setback

20 ft

Required space from a side street on a corner lot.

“All structures shall have a minimum side setback of 20 feet on the street side of a corner lot.”§ 11C-1307 · Garden City code · read 2026-10-01

Maximum building coverage

60 %

Share of the lot the building footprint may cover.

“In no zone shall a building or group of buildings with their accessory buildings cover more than sixty (60%) percent of the area of the lot.”§ 11C-915 · Garden City code · read 2026-10-01

Accessory structure setback

3 ft

Required space from a lot line for a shed, garage or other accessory structure.

“Accessory buildings shall have a 30’ front setback and a 3’ side or rear setback for up to a 15’ structure.”§ 11C-906 · Garden City code · read 2026-10-01

ADU max size

1,500 sf

Largest floor area an accessory dwelling unit may have.

“The ADU shall be limited in area to a maximum of 1,500 square feet”§ 11C-2300 · Garden City code · read 2026-10-01

Min dwelling size

600 sf

Smallest floor area a dwelling may have.

“All dwelling units must have a minimum of 600 square feet, with no side of the dwelling less than 12’ wide.”§ 11A-200 · Garden City code · read 2026-10-01

Max fence height

8 ft

How tall a fence may be.

“No fence or wall or other similar structure shall be erected in any required front, rear or side yard to a height in excess of eight (8) feet”§ 11C-908 · Garden City code · read 2026-10-01

Uses in MFR

  • single-familyAllowed by right
“11C-1302 Permitted Uses. A. Dwelling, single family”§ 11C-1302 · Garden City code · read 2026-10-01

Sources

Every figure above is quoted verbatim from the current ordinance. We never substitute a typical-for-zone default: a field absent from the record shows nothing, not a guess.

Other Garden City districts on record.

Check a real Garden City lot against MFR.

See how these standards resolve on a specific parcel, with the overlays that actually apply, in about 20 seconds.

Free to score · No card, no signup · All 50 states