Maximum height
28 ftHow tall the building may be.
“11-9N-3: SITE DEVELOPMENT STANDARDS … D. Building Height (in feet) 1. Minimum one story 10 2. Maximum two story 28”§ 11-9N-3.D · North Ogden code · read 2026-11-19
North Ogden, UT · zoning record
The dimensional standards that govern what you can build in the CF district, straight from North Ogden's ordinance, with every figure quoting its source. Check a specific address to see how these rules apply to a real lot.
Free · Every figure cited · Read from the current code (2026-11-19)
In North Ogden's CF district the maximum height is 28 ft (North Ogden code § 11-9N-3.D, read 2026-11-19).
In North Ogden's CF district the minimum lot size is 4,000 sq ft (North Ogden code § 11-9N-3.A, read 2026-11-19).
In North Ogden's CF district the minimum lot width is 40 ft (North Ogden code § 11-9N-3.B, read 2026-11-19).
In North Ogden's CF district the minimum front setback is 20 ft (North Ogden code § 11-9N-3.C, read 2026-11-19).
In North Ogden's CF district the minimum interior side setback is 5 ft (North Ogden code § 11-9N-3.C, read 2026-11-19).
In North Ogden's CF district the minimum street-side setback is 15 ft (North Ogden code § 11-9N-3.C, read 2026-11-19).
In North Ogden's CF district the minimum rear setback is 15 ft (North Ogden code § 11-9N-3.C, read 2026-11-19).
In North Ogden's CF district building coverage may not exceed 45% (North Ogden code § 11-9N-3.E, read 2026-11-19).
These are the letter-of-the-law limits for the base CF district. Overlays (historic, neighborhood plan, and similar) can tighten them; a specific address check resolves the overlays that actually apply.
How tall the building may be.
“11-9N-3: SITE DEVELOPMENT STANDARDS … D. Building Height (in feet) 1. Minimum one story 10 2. Maximum two story 28”§ 11-9N-3.D · North Ogden code · read 2026-11-19
Smallest conforming lot.
“11-9N-3: SITE DEVELOPMENT STANDARDS … A. Minimum lot area (square feet) 4,000”§ 11-9N-3.A · North Ogden code · read 2026-11-19
Narrowest conforming lot.
“11-9N-3: SITE DEVELOPMENT STANDARDS … B. Minimum lot width (square feet) 40”§ 11-9N-3.B · North Ogden code · read 2026-11-19
Required space from the front line.
“11-9N-3: SITE DEVELOPMENT STANDARDS … C. Minimum yard setback ( in feet) 1. Front 20 (18 feet if the house proceeds the garage)”§ 11-9N-3.C · North Ogden code · read 2026-11-19
Required space from a side line.
“11-9N-3: SITE DEVELOPMENT STANDARDS … 2. Interior Side 5”§ 11-9N-3.C · North Ogden code · read 2026-11-19
Required space from a side street on a corner lot.
§ 11-9N-3.C · North Ogden code · read 2026-11-19Row as published
“11-9N-3: SITE DEVELOPMENT STANDARDS … 3. Street side 15 (On lots numbered 14 and 34 the street side yard setback is 12 feet)”
Required space from the rear line.
“11-9N-3: SITE DEVELOPMENT STANDARDS … 5. Rear 15”§ 11-9N-3.C · North Ogden code · read 2026-11-19
Share of the lot the building footprint may cover.
“11-9N-3: SITE DEVELOPMENT STANDARDS … E. Maximum lot coverage percentage: 1. Under roof 45%”§ 11-9N-3.E · North Ogden code · read 2026-11-19
Every figure above is quoted verbatim from the current ordinance. We never substitute a typical-for-zone default: a field absent from the record shows nothing, not a guess.
See how these standards resolve on a specific parcel, with the overlays that actually apply, in about 20 seconds.
Free to score · No card, no signup · All 50 states