Maximum height
35 ftHow tall the building may be.
“11-9A-3: SITE DEVELOPMENT STANDARDS (Measurements in feet or square feet) … E. Building height 1. Minimum 10’ 2. Maximum 35’”§ 11-9A-3.E · North Ogden code · read 2026-11-19
North Ogden, UT · zoning record
The dimensional standards that govern what you can build in the RE-20 district, straight from North Ogden's ordinance, with every figure quoting its source. Check a specific address to see how these rules apply to a real lot.
Free · Every figure cited · Read from the current code (2026-11-19)
In North Ogden's RE-20 district the maximum height is 35 ft (North Ogden code § 11-9A-3.E, read 2026-11-19).
In North Ogden's RE-20 district the minimum lot size is 20,000 sq ft (North Ogden code § 11-9A-3.A, read 2026-11-19).
In North Ogden's RE-20 district the minimum lot width is 100 ft (North Ogden code § 11-9A-3.B, read 2026-11-19).
In North Ogden's RE-20 district the minimum front setback is 30 ft (North Ogden code § 11-9A-3.C, read 2026-11-19).
In North Ogden's RE-20 district the minimum interior side setback is 10 ft (North Ogden code § 11-9A-3.C, read 2026-11-19).
In North Ogden's RE-20 district the minimum street-side setback is 20 ft (North Ogden code § 11-9A-3.C, read 2026-11-19).
In North Ogden's RE-20 district the minimum rear setback is 50 ft (North Ogden code § 11-9A-3.C, read 2026-11-19).
These are the letter-of-the-law limits for the base RE-20 district. Overlays (historic, neighborhood plan, and similar) can tighten them; a specific address check resolves the overlays that actually apply.
How tall the building may be.
“11-9A-3: SITE DEVELOPMENT STANDARDS (Measurements in feet or square feet) … E. Building height 1. Minimum 10’ 2. Maximum 35’”§ 11-9A-3.E · North Ogden code · read 2026-11-19
Smallest conforming lot.
“11-9A-3: SITE DEVELOPMENT STANDARDS (Measurements in feet or square feet) … A. Minimum lot area: (sq. feet) 1. Interior or corner lot 20,000”§ 11-9A-3.A · North Ogden code · read 2026-11-19
Narrowest conforming lot.
“11-9A-3: SITE DEVELOPMENT STANDARDS (Measurements in feet or square feet) … B. Minimum lot width measured 30 feet back from the front property line 1. Interior lot 100’”§ 11-9A-3.B · North Ogden code · read 2026-11-19
Required space from the front line.
“11-9A-3: SITE DEVELOPMENT STANDARDS (Measurements in feet or square feet) … C. Minimum yard setbacks … 1. Front 30’”§ 11-9A-3.C · North Ogden code · read 2026-11-19
Required space from a side line.
“11-9A-3: SITE DEVELOPMENT STANDARDS (Measurements in feet or square feet) … 2. Side a. Dwelling 10’”§ 11-9A-3.C · North Ogden code · read 2026-11-19
Required space from a side street on a corner lot.
“11-9A-3: SITE DEVELOPMENT STANDARDS (Measurements in feet or square feet) … 3. Side facing street on corner lot 20’”§ 11-9A-3.C · North Ogden code · read 2026-11-19
Required space from the rear line.
“11-9A-3: SITE DEVELOPMENT STANDARDS (Measurements in feet or square feet) … 4. Rear 50’”§ 11-9A-3.C · North Ogden code · read 2026-11-19
Every figure above is quoted verbatim from the current ordinance. We never substitute a typical-for-zone default: a field absent from the record shows nothing, not a guess.
See how these standards resolve on a specific parcel, with the overlays that actually apply, in about 20 seconds.
Free to score · No card, no signup · All 50 states