Maximum height
35 ftHow tall the building may be.
“11-9J-3: SITE DEVELOPMENT STANDARDS (Measurements in feet and square feet) … 6. Building height a. Minimum 10' b. Maximum 35'”§ 11-9J-3.C · North Ogden code · read 2026-11-19
North Ogden, UT · zoning record
The dimensional standards that govern what you can build in the RCC district, straight from North Ogden's ordinance, with every figure quoting its source. Check a specific address to see how these rules apply to a real lot.
Free · Every figure cited · Read from the current code (2026-11-19)
In North Ogden's RCC district the maximum height is 35 ft (North Ogden code § 11-9J-3.C, read 2026-11-19).
In North Ogden's RCC district the minimum lot size is 8,000 sq ft (North Ogden code § 11-9J-3.A, read 2026-11-19).
In North Ogden's RCC district the minimum lot width is 80 ft (North Ogden code § 11-9J-3.B, read 2026-11-19).
In North Ogden's RCC district the minimum front setback is 30 ft (North Ogden code § 11-9J-3.C, read 2026-11-19).
In North Ogden's RCC district the minimum interior side setback is 8 ft (North Ogden code § 11-9J-3.C, read 2026-11-19).
In North Ogden's RCC district the minimum street-side setback is 20 ft (North Ogden code § 11-9J-3.C, read 2026-11-19).
In North Ogden's RCC district the minimum rear setback is 20 ft (North Ogden code § 11-9J-3.C, read 2026-11-19).
In North Ogden's RCC district building coverage may not exceed 35% (North Ogden code § 11-9J-3.C, read 2026-11-19).
These are the letter-of-the-law limits for the base RCC district. Overlays (historic, neighborhood plan, and similar) can tighten them; a specific address check resolves the overlays that actually apply.
How tall the building may be.
“11-9J-3: SITE DEVELOPMENT STANDARDS (Measurements in feet and square feet) … 6. Building height a. Minimum 10' b. Maximum 35'”§ 11-9J-3.C · North Ogden code · read 2026-11-19
Smallest conforming lot.
“11-9J-3: SITE DEVELOPMENT STANDARDS (Measurements in feet and square feet) … A. Minimum lot area 1. Interior with single-family dwelling 8,000 square feet”§ 11-9J-3.A · North Ogden code · read 2026-11-19
Narrowest conforming lot.
“11-9J-3: SITE DEVELOPMENT STANDARDS (Measurements in feet and square feet) … B. Minimum lot widths 1. For a single-family dwelling at a distance 30 feet back from the front property line 80'”§ 11-9J-3.B · North Ogden code · read 2026-11-19
Required space from the front line.
“11-9J-3: SITE DEVELOPMENT STANDARDS (Measurements in feet and square feet) … C. Minimum yard setback 1. Front 30'”§ 11-9J-3.C · North Ogden code · read 2026-11-19
Required space from a side line.
“11-9J-3: SITE DEVELOPMENT STANDARDS (Measurements in feet and square feet) … 2. Side: a. Single-family dwelling: 8'”§ 11-9J-3.C · North Ogden code · read 2026-11-19
Required space from a side street on a corner lot.
“11-9J-3: SITE DEVELOPMENT STANDARDS (Measurements in feet and square feet) … 3. Side facing street on corner lot 20'”§ 11-9J-3.C · North Ogden code · read 2026-11-19
Required space from the rear line.
“11-9J-3: SITE DEVELOPMENT STANDARDS (Measurements in feet and square feet) … 5. Rear: a. Main building 20'”§ 11-9J-3.C · North Ogden code · read 2026-11-19
Share of the lot the building footprint may cover.
“11-9J-3: SITE DEVELOPMENT STANDARDS (Measurements in feet and square feet) … 7. No building or group of buildings with accessory buildings shall cover more of the total lot area than 35%”§ 11-9J-3.C · North Ogden code · read 2026-11-19
Every figure above is quoted verbatim from the current ordinance. We never substitute a typical-for-zone default: a field absent from the record shows nothing, not a guess.
See how these standards resolve on a specific parcel, with the overlays that actually apply, in about 20 seconds.
Free to score · No card, no signup · All 50 states